DC Low Resistance Tester
Multi Channels
TH2518

■ Resistance range: 10uΩ - 200kΩ

■ Highest accuracy: 0.05%, resolution: 10uΩ

■ Temperature accuracy: 0.2 °C

■ Highest test speed: 600 times/s

■ Up to 90-channel resistance/temperature scan tests

■ Temperature compensation function (TC)

■ One-click screen capture function

■ Data logging function

■ The adopted test end of the scan test channel is 

   programmable

■ Support 6 units for free insertion and removal, 

   simultaneous measurement between test units

■ Temperature measurement can support PT100, PT500

   and analog voltage three temperature sampling methods

■ 4.3 inch 24-color touch LCD screen with 480 × 272 resolution

■ Chinese and English optional operation interface

■ Compatible with scanning and stand-alone measurement

   modes

■ Automatic upgrade of instrument operating software via 

   USB HOST

■ Comparison sort results of channel, board and 

   machine-level can be output

■ Handler interface for online operations

......
TH2518A

■ Resistance range: 10uΩ - 200kΩ

■ Highest accuracy: 0.05%, resolution: 10uΩ

■ Highest test speed: 600 times/s

■ One-click screen capture function

■ Data logging function

■ The adopted test end of the scan test channel is 

   programmable

■ Support 6 units for free insertion and removal, 

   simultaneous measurement between test units

■ 4.3 inch 24-color touch LCD screen with 480 × 272 resolution

■ Chinese and English optional operation interface

■ Compatible with scanning and stand-alone measurement

   modes

■ Automatic upgrade of instrument operating software via 

   USB HOST

■ Comparison sort results of channel, board and 

   machine-level can be output

■ Handler interface for online operations


......
Universal
TH2516

■ Resistance range: 1μΩ - 2MΩ

■ Highest accuracy: 0.05%, resolution: 1μΩ

■ Temperature accuracy: 0.2℃

 Highest sampling rate: 20ms

■ 24 bits, 4.3-inch and 4-wire touch LCD screen, resolution: 

   480×272 

■ Multiple measurement combinations of R, LPR, T

■ Low-voltage test mode, effectively protects DUT

■ Temperature conversion(Δt)

■ Temperature compensation(TC)

■ Offset voltage compensation(OVC)

■ Customer self-correction(0 ADJ)

■ Statistics function: CpK, Cp

 Simultaneously output compare results of 10 bins

   (OVER, PASS and BEEP)

 30 groups of parameter files can be saved and loaded

 Screen information can be stored on U-disk

 Data save function brings convenience for 

   saving measurement result

 Automatically update operation software through USB HOST

 Operation languages: Chinese and English

 Flexible and convenient file operation system

 Handler interface realizes on-line operation.

 Interfaces such as RS232, USB HOST, USB Device, and

   Handler

 Compatible with LXI C standard Specifications

......
TH2516A

■ Resistance range: 10μΩ - 200kΩ

■ Highest accuracy: 0.05%, resolution: 1μΩ

 Highest sampling rate: 20ms

■ 24 bits, 4.3-inch and 4-wire touch LCD screen, resolution: 

   480×272 

■ Multiple measurement combinations of R, LPR, T

■ Low-voltage test mode, effectively protects DUT

■ Offset voltage compensation(OVC)

■ Customer self-correction(0 ADJ)

■ Statistics function: CpK, Cp

 Simultaneously output compare results of 10 bins

   (OVER, PASS and BEEP)

 30 groups of parameter files can be saved and loaded

 Screen information can be stored on U-disk

 Data save function brings convenience for 

   saving measurement result

 Automatically update operation software through USB HOST

 Operation languages: Chinese and English

 Flexible and convenient file operation system

 Handler interface realizes on-line operation.

 Interfaces such as RS232, USB HOST, USB Device, and

   Handler

 Compatible with LXI C standard Specifications

......
TH2516B

■ Resistance range: 10μΩ - 20kΩ

■ Highest accuracy: 0.1%, resolution: 1μΩ

 Highest sampling rate: 20ms

■ 24 bits, 4.3-inch and 4-wire touch LCD screen, resolution: 

   480×272 

■ Multiple measurement combinations of R, LPR, T

■ Low-voltage test mode, effectively protects DUT

■ Offset voltage compensation(OVC)

■ Customer self-correction(0 ADJ)

■ Statistics function: CpK, Cp

 Simultaneously output compare results of 10 bins

   (OVER, PASS and BEEP)

 30 groups of parameter files can be saved and loaded

 Screen information can be stored on U-disk

 Data save function brings convenience for 

   saving measurement result

 Automatically update operation software through USB HOST

 Operation languages: Chinese and English

 Flexible and convenient file operation system

 Handler interface realizes on-line operation.

 Interfaces such as RS232, USB HOST, USB Device, and

   Handler

 Compatible with LXI C standard Specifications


......
High Performance Type
TH2515

■ Resistance range: 0.1μΩ - 110MΩ

■ Highest accuracy: 0.01%, resolution: 0.1μΩ

■ Temperature accuracy: 0.1℃

 Highest sampling rate: 10ms

■ 24 bits, 4.3-inch and 4-wire touch LCD screen, resolution: 

   480×272 

■ Intelligent detection for test state error

■ Multiple measurement combinations of R, LPR, T

■ Low-voltage test mode, effectively protects DUT

■ Temperature conversion(Δt)

■ Temperature compensation(TC)

■ Offset voltage compensation(OVC)

■ Customer self-correction(0 ADJ)

■ Statistics function: CpK, Cp

Simultaneously output compare results of 10 bins

   (OVER, PASS and BEEP)

 30 groups of parameter files can be saved and loaded

 Screen information can be stored on U-disk

 Data save function brings convenience for 

   saving measurement result

 Automatically update operation software through USB HOST

 Operation languages: Chinese and English

 Flexible and convenient file operation system

 Handler interface realizes on-line operation.

 Interfaces such as RS232, USB HOST, USB Device and

   LAN are available and GPIB is optional.

 Compatible with LXI C standard Specifications

......
Basic Model
TH2512+

■ Highest accuracy: ±0.05%

■ Maximum resolution: 1uΩ

■ Highest speed: 48ms

■ Comparator: High, low, pass, and Beep

 Clear function: Clear all ranges in AUTO range, and clear 

   the current range when the range is locked

■ 4 1/2 LED display

■ Direct reading value and percentage error dispaly


......
TH2512A+

■ Highest accuracy: ±0.05%

■ Maximum resolution: 10uΩ

■ Highest speed: 48ms

■ Comparator: High, low, pass, and Beep

 Clear function: Clear all ranges in AUTO range, and clear 

   the current range when the range is locked

■ 4 1/2 LED display

■ Direct reading value and percentage error dispaly



......
TH2512B+

■ Highest accuracy: ±0.1%

■ Maximum resolution: 1uΩ

■ Highest speed: 48ms

■ Comparator: High, low, pass, and Beep

 Clear function: Clear all ranges in AUTO range, and clear 

   the current range when the range is locked

■ 4 1/2 LED display

■ Direct reading value and percentage error dispaly



......