■ Output: 32V/6A(192W)
■ High precision and resolution: 0.1mV/0.01mA
■ High speed: 1ms
■ Voltage test, resistance test (build-in 5 1/2 digital
milliohmeter)
■ LCD resolution 480*272
■ Numeric keypad operation
■ Low ripple and low noise
■ Intelligent fan control to save energy and reduce noise
■ Software monitoring via computer
■ Editable voltage and current output waveform with time
(resolution 1ms) (LBT mode)
■ The power output can be turned on and off by an external
signal
■ The knob can be used to coarsely adjust and fine tune the
voltage and current values.
■ Timing output time can be set (0.01-9999.99S)
■ Screen information can be stored in the USB flash drive
■ Chinese and English user interface
■ Flexible and convenient file operating system
■ Automatic upgrade of instrument operating software via USB
HOST
■ Handler interface for online operations
■ RS232, USB HOST, USB Device, GPIB can easily realize
the data communication with PC and remote control of the
instrument
■ Comes with hardware OVP, OCP protection
(OCP is software protection)
■ R & D and design verification common test
■ Production line table routine testing and maintenance
■ Automated device integration testing
■ Solar photovoltaic simulation test
■ New power car simulation test
■ Teaching laboratory
Model | TH6501 | TH6502 | TH6503 | TH6511 | TH6512 | TH6513 | |
Rated Output | Voltage | 0-20V | 0-32V | 0-72V | 0-20V | 0-32V | 0-72V |
Current | 0-5A | 0-3A | 0-1.5A | 0-10A | 0-6A | 0-3A | |
Power | 100W | 96W | 108W | 200W | 192W | 216W | |
Load Regulation | Voltage | ≤0.01%+2mV | |||||
Current | ≤0.05%+1.5mA | ||||||
Power Regulation | Voltage | ≤0.01%+1mV | |||||
Current | ≤0.05%+1mA | ||||||
Set Value Resolution | Voltage | 1mV | |||||
Current | 0.1mA | ||||||
Read-back Resolution | Voltage | 0.1mV | |||||
Current | 0.01mA | ||||||
Year Set Accuracy (25℃±5℃) | Voltage | ≤0.03%+3mV | |||||
Current | ≤0.05%+2mA | ||||||
Year Read-back Accuracy(25℃±5℃) | Voltage | ≤0.02%+3mV | |||||
Current | ≤0.05%+2mA | ≤0.05%+2.5mA | |||||
Ripple and Noise(20Hz-20MHz) | Differential Mode Voltage | ≤3mVp-p and 1mVrms | ≤4mVp-p and 1mVrms | ||||
Differential Mode Current | <3mArms | <4mArms | |||||
Dynamic Recovery Time (50%-100% LOAD)Restore Time within 75mv | <200us | ||||||
Rise Time | 10%-90% | <20ms | |||||
Fall Time | 90%-10% | <200ms | <250ms | <150ms | <200ms | <250ms | <150ms |
Overvoltage Protection | Range (Typical) | 1-19V | 1-31V | 1-71V | 1-19V | 1-31V | 1-71V |
Accuracy (typical) | ± (set value *0.5%+0.5V) | ||||||
Response Time (typical) | <10ms | ||||||
DVM(DC) | Display Value Accuracy | ±0.02%+10mv | |||||
Display Resolution | 0.1mv | ||||||
Input Differential Mode Voltage Range | 0-40Vpk | ||||||
Input Common Mode Voltage Range | 0-30Vpk |
Standard | |||||
Accessories name | Model | ||||
Test line at both ends | TH26004C |
Optional | |||||
Accessories name | Model | ||||
High current test cable | TH26035D | ||||