■ Output power: 500W
■ Output voltage: 0-300V
■ Ourput frequency: 45.0Hz-500Hz
■ Linear output design
■ 24-bit color 4.3-inch 480 × 272 color LCD screen, Chinese
and English interfaces
■ Flexible and convenient operation: numeric keypad, coarse
and fine adjustment knob
■ Manual/program control mode output function, timing output
function, dimming mode output function, surge and notch
function
■ Front and rear panel output function
■ Boot hold function
■ Store setting parameters and test results
■ Support USB to upgrade the instrument firmware
■ Multiple protection modes: set the current protection (HI-A)
Overvoltage Protection (OVP), Low Voltage Protection (LVP)
Overcurrent protection (OCP), over power protection (OPP)
Over temperature protection (OTP)
■ Two-gear temperature to control fan speed
■ Remote input and output functions:
Remote input: input control of 7 groups of memory Remote
output: PASS, FAIL, PROCESSING, internal output switch
■ Memory capacity:
Manual: 50 groups
Program control: 50 groups, 9 steps / group
■ Motors and transformers
■ Electronic production design
■ Lighting
■ Aerospace military
■ Network communication
■ Audio and video equipment
■ Monitoring equipment
■ Power specifications simulation of different countries
■ Electromagnetic compatibility equipment
Model | TH7105 | TH7110 | TH7120 | |||
Output Parameters | ||||||
Rated Power | 500W | 1000W | 2000W | |||
Output Voltage | 0~300V | |||||
Output Frequency | 45.0Hz~500Hz | |||||
Maximum Current (RMS) | 0-150V | 4.2A | 8.4A | 16.8A | ||
0-300V | 2.1A | 4.2A | 8.4A | |||
MaximumCurrent (Peak) | 0-150V | 16.8A | 33.6A | 67.2A | ||
0-300V | 8.4A | 16.8A | 33.6A | |||
Total Harmonic Distortion (THD | at 45.0 ~ 500Hz, ≤ 0.5% (resistive load) | |||||
Commonparameters | Phase | 1Ø/2W | ||||
Crest Factor | ≥4 | |||||
Linearity Adjustment Rate | 0.1%±10% | |||||
Load Regulation | 0.5%(resistive load) | |||||
Response Time | <100uS | |||||
Setting Parameters | ||||||
Voltage | ~ 300V | Resolution | 0.1V | Accuracy | ±0.5%+2 digits | |
Frequency | 45.0Hz ~ 500Hz | <100Hz: 0.1Hz ; ≥100Hz: 1Hz | ±0.02% | |||
Initial / Final Phase Angle | ~ 359° | 1° | ±1°(45 ~ 65Hz) | |||
Measurement Parameters | ||||||
Voltage | ~ 300V | Resolution | 0.1V | Accuracy | ±0.5%+2 digits | |
Frequency | 45.0Hz ~ 500Hz | <100Hz: 0.1Hz ; ≥100Hz: 1Hz | ±0.1Hz | |||
Current | 0-150V | 0.000 ~ 4.200A | 0.000 ~ 8.400A | 0.000 ~ 16.800A | ||
0-300V | 0.000 ~ 2.100A | 0.000 ~ 4.200A | 0.000 ~ 8.400A | |||
Resolution | 0.001A | |||||
Accuracy | ±0.5%+5 digits | |||||
Peak Current | 0-150V | 0.00 ~ 16.80A | 0.00 ~ 33.60A | 0.00 ~ 67.20A | ||
0-300V | 0.00 ~ 8.40A | 0.00 ~ 16.80A | 0.00 ~ 33.60A | |||
Resolution | 0.01A | |||||
Accuracy | ±5%+2 digits | |||||
Power | Range | ~ 500W | ~ 1000W | ~ 2000W | ||
Resolution | 0.1W | 0.1W(0 ~ 1000W);1W(1000 ~ 2000W) | ||||
Accuracy | ±0.6%+5 digits | |||||
Power Factor | 0.001-1.000 | Resolution | 0.001 | Accuracy | ±2%+2 digits |
Standard | |||||
Accessories name | Model |
Optional | |||||
Accessories name | Model |