■ IR resistance test range: 10kΩ - 50TΩ
■ Charge current: 2mA , 25mA, 200mA
■ Test speed: 50ms
■ Accuracy: ±2% (< 1TΩ )
■ Test voltage range: 10-500V, 1V step
■ 320×240 dot-matrix LCD
■ Ultra-low leakage current test: minimum current is
10pA, accuracy: 2% ±2pA
■ Dual outputs (precharge voltage output and test
voltage output) can be set.
■ The precharge voltage output can be set to follow the test
voltage output and can be finely adjusted on test voltage.
Also the precharge voltage can be set to work in
independent mode.
■ 100W powerful charging function
■ Contact detection function for capacitive components
■ When the test current is less than 10nA, the internal input
impedance can be selected between 10kΩ and 1MΩ to
ensure rapid and accurate test.
■ 7 current ranges, manual or auto range mode
■ 4-bin comparison function
■ Programmable sequence test mode
■ R-T and I-T Curve test and display mode
■ Screen hardcopy to be saved as BMP file to a U disk
■ Automatically upgrade firmware by a U disk
■ Achieve automatic test system by Handler interface
■ Achieve remote control by RS232C and USB
Device interface
■ Support scanning interface for mass tests
■ Auto store setup parameters
■ Selectable Chinese and English operation interfaces
■ TH2684/TH2684A High Precision IR Tester is an intelligent measurement instrument that is used for rapid measurements on IR properties of electronic parts and components, dielectric materials, equipments, cables, etc. Large LCD and user friendly menu provide you easier operation.
This instrument is especially designed for capacitor IR test TH2684/TH2684A can achieve rapid measurements through following methods:
1. Selectable internal input impedance: If the current is greater than 10nA, only 10kΩ input impedance can be used; if the current is below 10nA, you can choose 10kΩ or 1MΩ impedance to test.
2. With the built-in dual voltage output, TH2684 can charge large capacitors. By dual voltage output, TH2684 is able to output a precharge voltage up to 500V, 200mA. In voltage follow mode, precharge voltage follow with the test voltage output and can be finely adjusted. Above features ensure the perfect charge of capacitive materials.
3. TH2684A can output a voltage of 1000V, 100mA to fully charge the capacitive material. In addition, user can program the sequence measurement steps (up to 18 steps) on TH2684/TH2684A. For instance, charge, wait, test, and discharge steps can be programmed. Each step can last up to 100s.
TH2684/TH2684A has a unique contact detection function. For capacitive material such as capacitors and cables, contact detection function can detect the contact of components under test. Moreover, this detection function will not increase any test time.
TH2684 equips with interfaces of RS232, USB DEVICE, SCANNING and Handler. Handler interface provide convenience for automatic test system; SCANNING interface is useful for mass measurement of components. User can use a scanner to speed measurement of components.
Model | TH2684 | TH2684A |
Resistance Test | ||
Range | kΩ to 50TΩ | kΩ to 100TΩ |
Accuracy | Test current > 100pA: 2%Test current ≤ 100 pA: 2% ± Vtest/2pA | |
Current Test | ||
Range | Range 1 :100uA – 1mA , Internal Input impedance 10 kΩ | |
Range 2 :10uA – 100uA , Internal Input impedance 10 kΩ | ||
Range 3 :1uA – 10uA , Internal Input impedance 10 kΩ | ||
Range 4 :100nA – 1uA , Internal Input impedance 10 kΩ | ||
Range 5 :10nA – 100nA, Internal Input impedance 10 kΩ | ||
Range 6 :1nA – 10nA, Internal Input impedance 10 kΩ or 1MΩ (selectable) | ||
Range 7 :10pA – 1nA, Internal Input impedance 10 kΩ or 1MΩ (selectable) | ||
Accuracy | 2% ± 2pA | |
Measurement Voltage | ||
Range | 10 to 500V, 1V resolution | to 1000V,1V resolution |
Accuracy | 2% of readout,or ± 1V | |
Source Resistance | 200Ω | |
Current Limit | 2,25,or 200mA | 2, 25 , or 100mA |
Voltage Output | Manually turn on or off on front panel, or controlled by built-in timer, or by remote control. | |
Timing | Programmable charge time: 0 to 1000s | |
Measurement Delay | 0 to 1000s programmable | |
Discharge Resistance | 2kΩ | |
Discharge Time | t = 0.03 x Cx (in μF), when Vtest falls to 1% of the test level. | |
Measurement Speed | ||
Trig Mode | Single measurement: < 100ms(exclude charge time)Average up to 100 measurements:<100+ (N-1) x 100 ms (exclude charge) | |
Continuous Mode | Direct readout: 100ms – 10000ms depending on average number | |
Comparator | bins:(3 bins for PASS,1 bin for FAIL) | |
Range Mode | Auto, Hold | |
Average Times | to100 | |
Memory | Sets of setup values can be stored. | |
Standard Interface | GPIB (optional), RS232C, HANDLER interface output, USBDEVICE ( USBTMC and USBCDC support), USBHOST, SCANNING |
Operating Temperature and Humidity | 10°C - 40°C, ≤90%RH |
Power Supply | to 130 V AC(60Hz) orto 260V AC(50HZ) |
Power Consumption | TH2684 : 250WTH2684A: 150W |
Dimensions (W×H×D) | 430mm×400mm×130mm |
Weight | TH2684 : 14kgTH2684A: 10kg |
Standard | |||||
Accessories name | Model | ||||
Test line at both ends | TH26004B |
Optional | |||||
Accessories name | Model |